Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 79: 414-420, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34644650

RESUMO

BACKGROUND: Hybrid Deep Venous ARterialisation (DVAR) is offered as a last-ditch attempt for limb salvage in patients with chronic limb threatening ischemia (CLTI). It provides non-selective arterialisation independent of the angiosome, which harnesses the complex venous capillary network bed developed in the leg and foot. METHODS: We present two elderly men who underwent DVAR to salvage limb with CLTI. DVAR was performed by creating an arteriovenous connection by anastomosis of the great saphenous vein (GSV) at the level of the distal popliteal and proximal tibio-peroneal trunk. Fasciotomy was performed over the length of the GSV. Subsequently, proximal in-situ catheter valvotomies of the GSV valves were undergone with the adjuvant on-table balloon maturation. The distal tarsal veins underwent balloon valvotomy under direct vision with subsequent proximal and distal tarsal veins valvuloplasties. Completion angiogram demonstrated restoration of the flow in the foot and both the patients were relieved of rest pain. CONCLUSION: We successfully performed DVAR in 2 elderly patients. Our experience shows that DVAR is a simple and safe option that is easily reproducible without the need for complex endovascular hardware, only if a suitable GSV to the foot is available with no history of deep vein thrombosis.


Assuntos
Procedimentos Endovasculares , Pé/irrigação sanguínea , Isquemia/cirurgia , Doença Arterial Periférica/cirurgia , Artéria Poplítea/cirurgia , Veia Safena/cirurgia , Artérias da Tíbia/cirurgia , Idoso , Doença Crônica , Procedimentos Endovasculares/efeitos adversos , Fasciotomia , Humanos , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Salvamento de Membro , Masculino , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Fluxo Sanguíneo Regional , Veia Safena/diagnóstico por imagem , Veia Safena/fisiopatologia , Artérias da Tíbia/diagnóstico por imagem , Artérias da Tíbia/fisiopatologia , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
Eur Heart J Case Rep ; 5(10): ytab339, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34622129

RESUMO

BACKGROUND: Thoracic and abdominal aortic stent grafts are firmer and more rigid than the native aorta. Aortic implanted devices have been implicated in the development of acute systolic hypertension, elevated pulse pressure, and reduced coronary perfusion. CASE SUMMARY: We report four cases of staged thoracic endovascular aortic repair (TEVAR) and then endovascular aneurysm repair (EVAR). All patients had TEVAR first for thoracic aortic aneurysm and later on developed infra-renal abdominal aortic aneurysm (AAA) that required EVAR. There were three males and one female with a median age of 74.5 years (range 67.5-78.5). None of the patients developed aortic-related major clinical adverse effects or required any aortic intervention during their follow-up. However, within 2 years, all patients developed symptomatic left ventricular hypertrophy with diastolic dysfunction. All patients had bilateral lower limb oedema, with on and off chest pain and shortness of breath (SOB), necessitating coronary angiograms, which showed no evidence of coronary artery disease. Three patients died from cardiovascular-related morbidities, and the fourth patient is still complaining of SOB despite a normal coronary angiogram. DISCUSSION: Aortic-endograft compliance mismatch is an invisible enemy, with troubling consequences for the aorta proximal and distal to the endograft. Aortic stiffness due to vascular endograft could lead to cardiovascular adverse events, even in the absence of direct aortic-related complications. After combined TEVAR and EVAR, the compliance mismatch and elasticity loss are even more pronounced than with TEVAR alone, which necessitates patient monitoring for the development of cardiovascular complications.

3.
BMJ Case Rep ; 14(8)2021 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-34433533

RESUMO

We present a 54-year-old Caucasian woman, who presented with acute symptomatic type B aortic dissection with deteriorating renal function. She was a known smoker with a 2-year history of dysphagia. CT angiography documented the artery of lusoria arising from the mid-thoracic aorta, aneurysmal dilation of her descending aorta, and kinetic and static flaps around her visceral ostia. The patient was managed by staged hybrid single lumen reconstruction and bilateral subclavian to carotid transpositions. During follow-up, there was no aortic rupture or retrograde type A dissection. There were no renal, visceral, cardiac, pulmonary or spinal complications. The patient went off her antihypertensive medication with a normal estimated glomerular filtration rate and accelerated aortic modulation.


Assuntos
Aneurisma da Aorta Abdominal , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...